Analog-way Eikos LE - EKS400 Programmer's Guide Manuel d'utilisateur Page 16

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 74
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 15
16
Group Name Cmd
RespDescription
Read /
Write
Min
Value
Max
value
Default
value
Values Index #1 Index #2
IN_KEYING_INVERT KI KI Invert keying area Rd/Wr 0 1 0
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14
IN_KEYING_GRAB_ENABLE Kg Kg
Enable/disable the keying color
grabber mode
Rd/Wr 0 1 0
0 = Disable the grabber
1 = Enable the grabber
IN_KEYING_GRAB_GET Kc Kc
Capture the coolor selected by the
grabber and apply the settings
Rd/Wr 0 1 0 Percent of OSCREEN_UTIL_H
IN_KEYING_GRAB_H Kh Kh Horizontal position of the grabber Rd/Wr 0 65535
32768 Precent of OSCREEN_UTIL_V
IN_KEYING_GRAB_V Kv Kv Vertical position of the grabber Rd/Wr 0 65535
32768
INPUT
STATUS
SIG_HPOL sh sh Input H sync polarity Rd 0 1 0
0 = Negative Synchro
1 = Positive Synchro
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14
SIG_VPOL sv sv Input V sync polarity Rd 0 1 0
0 = Negative Synchro
1 = Positive Synchro
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14