CONNECTING
SETUP MENU
ADDITIVE MODULARITY
To link the 2 units, you need to connect the Web RCS to the
SmartMatriX Ultra or Ascender 16. Please enter the IP address
of the SmartMatriX Ultra or Ascender 16 into your web browser.
Once connected go into then Link.
Switch from SINGLE MODE to LINK MODE. At this point you
should have the LiveCore™ Output Expander IP address and
the connecon status. If any of the cable are red, that means
one of the cable is not well connected. You can refresh the cable
connecon status clicking on the refresh buon.
Please click on PROCEED to launch the addive modularity.
The two units will reboot and the Web RCS will be load again to
nish the process.
Now, with only one Web RCS, you have access to a 12 inputs
and 8 outputs units with 2 monitoring outputs with 2 layers per
screens
Please go into the to congure the screen
posion and start building your show.
You need to connect rst of all units with an RJ45 cable to the
Ethernet hub in order to communicate with the computer.
Then you need to connect a RJ45 STRAIGHT cable for the specic
synchronizaon between the SmartMatriX Ultra or Ascender 16
and the LiveCore™ Output Expander (LOE016), see the red cable
in the schemacs.
Finally, you need to connect the 3 data cables (link cable) from the
rst unit to the second unit. Link1 has to be plug with link1, link2
with link2 etc…
Ascender 16
LiveCore™ Output Expander (LOE016)
RJ-45
OPT-LINK (x3)
LINK 1
LINK 2
LINK 3
RJ-45
OUT IN
Web RCS
(Remote Control Soware)
On Device Master
ETHERNET HUB