Analog-way OPS300 Programmer's Guide Manuel d'utilisateur Page 15

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 58
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 14
15
Group Name Cmd
Resp
Description
Read /
Write
Min
value
Max
value
Default
value
Values Index #1 Index #2
SIG_SYNC_TYPE sK sK Input sync type Rd 0 3 0
0 = Séparated Synchros H&V
1 = Composite TTL Synchro
2 = Composite Analog Synchro
3 = Synchro on Green (SOG)
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
7 = Input8
8 = Input9
9 = Input10
10 = Input11
11 = Input12
SIG_FREQ_FIELD sf sf Input frame frequency Rd 0 65535
0 Unit = 1/100Hz
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
7 = Input8
8 = Input9
9 = Input10
10 = Input11
11 = Input12
SIG_FREQ_LINE sl sl Input line frequency Rd 0 65535
0 Unit = 1/100Hz
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
7 = Input8
8 = Input9
9 = Input10
10 = Input11
11 = Input12