Analog-way PULSE LE - Ref. PLS200 Programmer's Guide Manuel d'utilisateur Page 21

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 52
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 20
21
Group
Name CmdResp
Description
Read
/
Write
Min
Value
Max
value
Default
value
Values Index #1 Index #2
SIG_MEM_SLOT sS sS Memory slot index Rd 0 255 255
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
INPUT
SETTINGS
SET_HPOS SH SH Input horizontal position
Rd/Wr
0 2048 1024 1024 = neutral
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
SET_VPOS SV SV Input vertical position
Rd/Wr
0 2048 1024 1024 = neutral
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
SET_HSIZE Sw Sw Input horizontal size
Rd/Wr
0 4096 2048 2048 = neutral
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
Vue de la page 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 51 52

Commentaires sur ces manuels

Pas de commentaire