Group
Name CmdResp
Description
Read
/
Write
Min
Value
Max
value
Default
value
Values Index #1 Index #2
REFERENCE
REFREQUEST
Xr
Xr
Framelock source requested
by user
Rd/Wr
0 15 0
0 = Analog input 1 as reference
1 = Analog input 2 as reference
2 = Analog input 3 as reference
3 = Analog input 4 as reference
4 = Analog input 5 as reference
5 = Analog input 6 as reference
8 = DVI 1 input as reference
9 = DVI 2 input as reference
10 = SDI 1 input as reference
11 = SDI 2 input as reference
14 = Back End 1 as reference
15 = Back End 2 as reference
0 = Main output
1 = Preview
output
REFCURRENTREQUEST
Xe
Xe
Current Frame Lock source
Rd/Wr
0 15 0
0 = Analog input 1 as reference
1 = Analog input 2 as reference
2 = Analog input 3 as reference
3 = Analog input 4 as reference
4 = Analog input 5 as reference
5 = Analog input 6 as reference
8 = DVI 1 input as reference
9 = DVI 2 input as reference
10 = SDI 1 input as reference
11 = SDI 2 input as reference
14 = Back End 1 as reference
15 = Back End 2 as reference
0 = Main output
1 = Preview
output
REFMODE
Xm
Xm
Follow mode requested by user
Rd/Wr
0 5 0
0 = Internal
1 = Follow x1/2
2 = Follow x1
3 = Follow x2
4 = Follow x3
5 = Asynchronous Follow
0 = Main output
1 = Preview
output
REFCURRENTMODE
Xc
Xc
Current follow mode
Rd/Wr
0 5 0
0 = Internal
1 = Follow x1/2
2 = Follow x1
3 = Follow x2
4 = Follow x3
5 = Asynchronous Follow
0 = Main output
1 = Preview
output
REFFREQ
Xt
Xt
Frame rate of the reference
signal
Rd 0 655350 Unit = 1/100Hz
0 = Main output
1 = Preview
output