5
Group Name Cmd
RespDescription
Read /
Write
Min
Value
Max
value
Default
value
Values Index #1 Index #2
Index #3
SYSTEM
DIESE # #
Request the retrieval of all the
variables
Rd/Wr
0 1 0
READY * * Ready Device Flag Rd 0 1 0
0= Initialization in progress
1 = Ready
DEV ? DEV
MMS device type Rd 94 94 94 94 = STE_200
CONTROLS
UPDATER yU yU Device reboot for update Rd/Wr
0 255 0 1 then 254 => Reboot
FACTORYRESET YR
YR
Apply factory settings to the
device( except image settings )
Rd/Wr
0 1 0
Auto reset
POSMEMORYRESET YE
YE Erase stored image settings Rd/Wr
0 1 0
Auto reset
CSTORE YS
YS
FLASH memory writing in progess.
Do not power off
Rd 0 1 0
0 = Free
1 = Flash writing in progress
LOCK YK
YK Device locking Rd/Wr
0 2 0
0 = No lock
1 = Locked menu
2 = Locked front panel
LCDBRIGHTNESS YB
YB Front panel display brightness Rd/Wr
1 8 8
1, …, 8 = Brightness level,
12,5% step
KEYBRIGHTNESS Yb Yb Front panel keys brightness Rd/Wr
10 100 100
1, …, 100 = Brightness level,
1% step
TBAR_ENABLE YD
YD
Enable disable T-BAR Rd/Wr
0 1 1
COPKIND CK
CK
Kind of slow in-progress operation
Rd 0 6 0
0 = None
1 = Auto centering
2 = Auto setting
3 = StandBy
4 = Picture recording
5 = Reset to default factory
setting
6 = Reset User settings
COPPROGRESS CP
CP
Progress percent of the slow
operation
Rd 0 100 0 Percent : 0 to 100%
SWITCHER_MODE CM
CM
Device operating mode Rd/Wr
1 1 0 1 = Matrix mode
AXION
yA yA Device is driven by Orchestra Rd/Wr
0 1 0
0 = Device is not driven by
ORC-50
1 = Device is driven by Orc-
50
AUTO_LOCK
YL YL
Forbide the use of a signal-less
input
Rd/Wr
0 1 1
0 = Signal less input can be
selected
1 = Signal less input can not
be selected
AUTO_TAKE
YT YT
Automatic Take after an input
change
Rd/Wr
0 1 0
0 = AUTO-TAKE Disable
1 = AUTO-TAKE Enable
AUTO_STEPBACK
Ys Ys
Automatic preset toggle after a
TAKE
Rd/Wr
0 1 0
0 = AUTO- PRESET-
TOGGLE Disable
1 = AUTO- PRESET-
TOGGLE Enable
FREEZE_MODE Ym
Ym
Input freeze mode Rd/Wr
0 1 0
0 = Freeze by input
1 = Freeze all inputs