Group Name Cmd
RespDescription
Read /
Write
Min
Value
Max
value
Default
value
Values Index #1 Index #2
Index #3
PSTATUS_STYLE Ps Ps Logo style Rd 0 2 0
0 = Normal logo
1 = Animated logo
2 = Frame
1 = Logo 1
2 = Logo 2
3 = Logo 3
4 = Logo 4
9 = Frame 1
10 = Frame 2
11 = Frame 3
12 = Frame 4
PSTATUS_FRAME_COUNT Pn Pn
Number of frames of an animated
logo
Rd 1 255 1
1 = Logo 1
2 = Logo 2
3 = Logo 3
4 = Logo 4
9 = Frame 1
10 = Frame 2
11 = Frame 3
12 = Frame 4
PSTATUS_REFRESH_INTERVAL Pi Pi
Time between 2 frames of an
animated logo
Rd/Wr
1 10000
56 Unit = 1ms
1 = Logo 1
2 = Logo 2
3 = Logo 3
4 = Logo 4
9 = Frame 1
10 = Frame 2
11 = Frame 3
12 = Frame 4
LAN
LANENABLE ne ne LAN enable Rd/Wr
0 1 0
0 = Enable RS232 ( disable
LAN )
1 = Enable LAN ( disable
RS232 )
LANRESET nr nr LAN factory parameters reset Rd/Wr
0 1 0
Auto reset
LANSTORE ns ns LAN parameters update Rd/Wr
0 1 0
Auto reset
LANIP nw nw LAN devices addresses Rd/Wr
0 255 192 IP : 0 to 255
0 = Device
1 = Remote
2 = Gateway
0 = IP address
high byte
1 = IP address
mid high byte
2 = IP address
mid low high
byte
3 = IP address
low byte
LANPORT np np LAN port numbers Rd/Wr
0 65535
10500
Local port : 10000 à 10999
Remote port : 0 à 65500
0 = Device
1 = Remote
2 = Gateway
LANNETMASK nk nk LAN netmask Rd/Wr
0 24 8
Number of 0bits from the